UL 1598 Explained: The Standard for High Bay Lights

Steve Shepherd |

The Critical Role of UL 1598 in Industrial Lighting Specification

For facility managers and electrical contractors, the presence of a UL Listing mark on a high bay light is the primary indicator of safety and code compliance. In the North American market, UL 1598 (the Standard for Luminaires) serves as the definitive technical benchmark for fixed-position lighting. Specifying a product that adheres to this standard is a pragmatic necessity for meeting the National Electrical Code (NEC), securing insurance coverage, and qualifying for utility rebates.

Key Takeaways for B2B Specifiers:

  • Who Benefits: Contractors and facility managers use UL 1598 as a shield against liability and "rip-and-replace" costs.
  • Core Conclusion: A UL 1598 certification verifies that a luminaire has undergone standardized testing for thermal management, electrical safety, and mechanical integrity.
  • Compliance Reality: While regional enforcement varies, luminaires without this certification are generally not permitted for installation in most commercial and industrial jurisdictions under NEC Article 410.

According to the 2026 Commercial & Industrial LED Lighting Outlook, the evolution of LED technology has forced UL 1598 to become more complex, particularly regarding how heat affects internal components like drivers and gaskets over long-term operation.

Understanding the UL 1598 Framework

UL 1598 is a bi-national standard, harmonized between the United States (ANSI/UL 1598) and Canada (CAN/CSA-C22.2 No. 250.0). This harmonization allows manufacturers to obtain a single "cULus" mark, though evaluation processes often remain distinct.

The "Compliance Tax" of cULus

While the standards are harmonized, professional auditors often point to a "compliance tax" inherent in the process. As noted in the UL 1598 5th Edition Brochure, both the CSA Group and UL Solutions typically conduct their own evaluations. For the contractor, this can translate to higher equipment costs, as manufacturers navigate double fees and administrative overhead to maintain these dual marks.

UL Listed vs. UL Recognized

A common pitfall in B2B procurement is confusing "UL Listed" with "UL Recognized."

  • UL Listed: Applies to the entire finished luminaire. It indicates the fixture is ready for field installation as a complete unit.
  • UL Recognized: Applies only to individual components (like an LED driver). A fixture containing UL Recognized parts is not automatically a UL Listed fixture.

Field Note: We have observed instances where contractors used non-listed accessories (such as third-party motion sensors) on UL Listed high bays. In one industrial warehouse retrofit, the local inspector flagged the non-compliant assembly, requiring the contractor to remove the sensors to maintain the fixture's listing, which resulted in significant labor delays.

For project compliance, always verify that the entire assembly carries the UL Listed mark. You can cross-reference these in the UL Solutions Product iQ Database.

LED High Bay lights in a high-ceiling warehouse with light meter and IES lighting standards clipboard

Core Testing Requirements for High Bay Lights

High bay lights operate in demanding environments—often at heights exceeding 20 feet where ambient temperatures can fluctuate significantly. UL 1598 addresses these risks through four primary testing categories.

1. Thermal Management (The Normal Conditions Test)

The most critical failure mode for industrial LEDs is thermal degradation. UL 1598 requires a "Temperature Test" where the fixture is operated in a controlled environment until it reaches thermal equilibrium.

The test measures the temperature of every critical component—LED chips, drivers, wiring, and gaskets—to ensure they do not exceed their rated limits. The 5th Edition of UL 1598 introduced a more rigorous 168-hour thermal aging test for gaskets and bushings, testing them at 20°C above their maximum normal operating temperature to simulate cumulative stress.

2. Electrical Safety and Grounding

To mitigate fire and shock hazards, the standard mandates:

  • Dielectric Voltage-Withstand: Verifying insulation can handle high-voltage surges without breakdown.
  • Grounding Continuity: Ensuring exposed metal parts are effectively bonded to the equipment grounding conductor.
  • Wiring Protection: Ensuring internal wires are protected from sharp edges and high-heat zones.

3. Mechanical Integrity and Strain Relief

High bays are heavy and often subject to vibration. UL 1598 tests the strength of mounting hooks, brackets, and the strain relief of the power cord. For fixtures in high-traffic warehouses, specifiers often look for IK Ratings (IEC 62262) to complement UL safety data.

4. Environmental Location Ratings

UL 1598 classifies luminaires based on their intended environment. Note that local jurisdictions may have specific interpretations of these ratings.

Feature Dry Location Damp Location Wet Location
Water Exposure None Condensation/Moisture Direct Spray/Rain
Sealing Required Minimal Gasketed joints Full enclosure/IP65+
Typical Application Retail Showrooms Cold Storage Car Washes/Outdoor

Expert Insight: A common misconception is that a "Damp Location" rating is sufficient for industrial washdowns. However, UL 1598 location ratings do not automatically mandate a specific Ingress Protection (IP) code. For environments where high-pressure cleaning occurs, specifiers should verify both the UL Wet Location listing and a minimum IP65 or IP66 rating.

Technician inspecting machined aluminum housings for an LED High Bay fixture on a factory bench

The Link Between UL 1598 and Real-World Longevity

While UL 1598 is a safety standard, its thermal data provides the foundation for performance metrics. There is a strong correlation between the thermal management validated by UL and the lumen maintenance (L70) of the fixture.

The Driver Capacitor Rule of Thumb

Even if a fixture passes the UL Temperature Test, it may face longevity issues if operated at its absolute thermal limit. For example, if a driver's electrolytic capacitor is rated for 105°C and the UL test shows it operating at 104°C, the fixture passes safety requirements.

However, in the field, operating a capacitor at its limit drastically reduces its lifespan. A common engineering heuristic—the Arrhenius-based "10-degree rule"—suggests that for every 10°C increase in operating temperature, the life of an electrolytic capacitor is roughly halved.

Illustrative Modeling: Thermal Stress vs. ROI

The table below models how thermal design choices impact projected maintenance cycles.

Parameter Standard Build High-Performance Build Unit Rationale
Tested Capacitor Temp 100 85 °C UL 1598 Thermal Test
Ambient Rating 40 50 °C Manufacturer Spec
Estimated Driver Life ~30,000 ~60,000+ Hours Arrhenius Rule of Thumb
L70 Projection 50,000 100,000 Hours TM-21-21 Standard
Maintenance Cycle ~5-7 Years 10+ Years Years Estimated (12h/day use)

Modeling Note: These values are deterministic estimates based on standard component degradation heuristics and TM-21 projections. Actual results vary based on site-specific airflow, driver quality, and power stability.

Code Compliance and Rebate Eligibility

National Electrical Code (NEC) Requirements

The NEC (NFPA 70) is the legal standard for electrical installations in the US. Article 410 specifically covers luminaires. Installing non-listed equipment in a commercial building can result in a failed inspection, potentially forcing a costly "rip and replace" scenario. Always check with your local Authority Having Jurisdiction (AHJ) for specific regional amendments.

DLC Premium and Utility Rebates

Most utility companies require products to be listed on the DesignLights Consortium (DLC) Qualified Products List (QPL) to qualify for financial incentives. For a 200W high bay, a DLC Premium certification (which requires UL 1598 compliance) can unlock rebates.

  • Estimated Rebate Range: Often $40 to $100 per fixture.
  • Variable Factors: These amounts vary significantly by utility provider, region, and current energy efficiency programs.
  • Prerequisite: The DLC will typically not evaluate a product unless it first holds a safety certification from an NRTL like UL or ETL.

Technicians servicing LED High Bay and LED shop lights in a high-ceiling warehouse

How to Verify UL Compliance: A Contractor’s Checklist

To ensure your project is protected, follow these verification steps:

  1. Request the UL File Number: Every certified product has a unique file number (e.g., E123456).
  2. Verify via Product iQ: Enter the file number into the UL Solutions Product iQ Database. Ensure the manufacturer and model numbers match exactly.
  3. Check the "Scope of Listing": Confirm the listing covers the specific mounting method (pendant, surface, or hook) intended for use.
  4. Beware of Accessories: Using a non-listed reflector or battery backup kit can void the UL Listing of the entire fixture. Ensure accessories are covered under the same report or are "UL Classified" for the specific fixture.
  5. Review the LM-79 Report: While UL 1598 proves safety, the IES LM-79-19 report proves performance (lumens, efficacy).

The Pragmatic Value of the UL Mark

In the B2B lighting sector, the UL 1598 mark is more than a sticker—it is a legal and technical shield. It represents a manufacturer’s commitment to engineering over marketing. By ensuring your high bay lights meet this standard, you help protect your facility from fire risks, your business from liability, and your budget through rebate eligibility.


YMYL Disclaimer: This article is for informational purposes only and does not constitute professional electrical engineering, legal, or financial advice. Always consult with a licensed electrician and local building authorities to ensure compliance with the National Electrical Code (NEC) and local regulations.