Grid vs. Row: UFO and Linear Uniformity for Large Gyms

Richard Miller |

Designing lighting for large athletic spaces, such as professional gymnasiums or multi-purpose sports complexes, requires a departure from standard warehouse lighting logic. In a high-ceiling warehouse, the primary goal is often aisle visibility; in a gymnasium, the objective is high-speed visual acuity, athlete safety, and increasingly, broadcast-quality consistency. Achieving a professional-grade uniformity—typically defined by a 4:1 or better maximum-to-minimum foot-candle (fc) ratio—is less about raw lumen output and more about the strategic selection of fixture geometry and beam distribution.

For facility managers and lighting designers, the decision usually centers on two primary configurations: a grid pattern utilizing round "high bay" fixtures or a row pattern utilizing linear high bay fixtures. While both can technically meet illuminance targets, their performance in terms of uniformity gradient, glare control (UGR), and total cost of ownership (TCO) differs significantly. This analysis explores the technical mechanisms behind these two layouts, supported by simulated performance data and industry standards, including the 2026 Commercial & Industrial LED Lighting Outlook: The Guide to Project-Ready High Bays & Shop Lights.

The Physics of Uniformity in Sports Lighting

Uniformity in lighting is not a single metric but a relationship between the brightest and darkest points on the playing surface. According to the ANSI/IES RP-7 - Lighting Industrial Facilities, professional sports environments require high levels of vertical and horizontal illuminance to ensure that fast-moving objects (like a basketball or volleyball) remain visible from all angles.

The two key metrics used to evaluate this are:

  1. Uniformity Ratio (Max/Min): The ratio of the maximum illuminance to the minimum illuminance. A ratio of 3:1 is considered excellent for community sports, while 2:1 is often required for televised professional events.
  2. Uniformity Gradient: The rate at which light levels change between adjacent points. A sharp drop-off in light—even if the overall ratio is acceptable—can cause visual disorientation for players during rapid eye movements.

In large gyms with mounting heights between 20 and 35 feet, the interaction between fixture spacing and beam angle determines these ratios.

UFO Grid Layout: The Symmetric Approach

The round "UFO" style high bay is the industry standard for open-area illumination. These fixtures typically feature a symmetric 120° beam angle, which creates a circular "pool" of light.

The Mechanism of Overlap To achieve uniformity with UFO fixtures, designers rely on the "Spacing Criteria" (SC). If a fixture has an SC of 1.3 and is mounted at 25 feet, the fixtures should be spaced no more than 32.5 feet apart to ensure the beams overlap at the floor level. In a grid pattern, this overlap is multi-directional, which is effective at filling in shadows in the center of the space.

The "Hot Spot" Friction Point A common mechanical issue with UFO grids in gym environments is the creation of "hot spots" directly beneath the fixtures. Because the light intensity is highest at the center of the beam (nadir), a grid pattern can result in a series of bright peaks and dimmer valleys. For broadcast cameras, these peaks can cause "flare," making it difficult to maintain consistent exposure across the court. Furthermore, if the mounting height is lower than 20 feet, a 120° beam may spread light too wide, wasting lumens on the upper walls rather than the playing surface.

High-ceiling industrial warehouse and assembly floor with polished concrete aisles, storage racks, HVAC duct runs, and evenly spaced LED high bay fixtures providing bright, uniform illumination

Linear Row Layout: Asymmetric Precision

Linear high bays are increasingly specified for gyms because their rectangular form factor allows for a different optical strategy. Most premium linear fixtures offer a 90° or 110° beam angle, which is more concentrated than the standard UFO.

The Parallel Sightline Advantage By aligning rows of linear fixtures parallel to the length of the court (e.g., following the sidelines), designers can create continuous "bands" of light. This configuration is particularly effective for sports like basketball or tennis, where players frequently look along the length of the court. The linear geometry reduces the "strobe effect" that can occur when a player runs through alternating bright and dark spots in a poorly spaced grid.

Overlapping Row Dynamics In a row layout, uniformity is achieved by the longitudinal overlap of fixtures within the row. Because linear fixtures often have a higher Coefficient of Utilization (CU)—meaning a higher percentage of the lamp's lumens actually reach the work plane—they can often achieve target foot-candles with lower total system wattage than a symmetric grid.

Data Deep Dive: 94' x 50' Gymnasium Simulation

To quantify the difference between these two approaches, we simulated a professional-grade basketball court (94' x 50') with a 25-foot mounting height. The target was 87.5 fc, suitable for high-level competition and local broadcast.

Performance Metric UFO Grid Layout Linear Row Layout
Fixture Count 22 Fixtures 29 Fixtures
Wattage per Fixture 360W 240W
Total System Wattage 7.92 kW 6.96 kW
Uniformity Ratio (Max/Min) 3.8:1 2.4:1
Annual Energy Savings vs. HID $5,069 $7,934
Estimated Payback Period 1.16 Years 0.75 Years

Data Context: Savings calculated based on 3,000 annual operating hours at $0.12/kWh, replacing 1000W Metal Halide fixtures. Energy savings include an interactive HVAC cooling credit (factor 0.33, COP 3.5).

Analysis of the Results The simulation reveals a non-obvious insight: More fixtures can lead to higher savings. While the linear layout required 7 more fixtures than the UFO grid, the lower wattage per fixture (240W vs 360W) reduced the total system load by nearly 1 kW. More importantly, the linear layout achieved a significantly better uniformity ratio (2.4:1 vs 3.8:1). The higher fixture count in the linear rows created more points of light, which smoothed out the uniformity gradient and eliminated the "dark valleys" between fixtures.

High‑ceiling industrial warehouse interior with suspended LED high bay fixtures casting focused beams over pallet racking and storage aisles; tablet screen shows comparative photometric layouts and beam spread for lighting design, retrofit and DLC/IES spec use.

Glare Control and the Player Experience

One of the most critical, yet overlooked, factors in gym lighting is the Unified Glare Rating (UGR). In sports like volleyball or basketball, players are constantly looking upward. A fixture that is "bright" but lacks glare control can temporarily blind an athlete, leading to missed plays or injury.

According to the IES LM-79-19 Standard for Optical and Electrical Measurement, photometric reports must detail the distribution of light. For gym applications, fixtures with prismatic lenses or micro-louvered optics are preferred.

  • UFO Fixtures: Often rely on a single flat lens. To reduce glare, they may require external reflectors or "frosted" lenses, which can reduce efficacy (lumens per watt).
  • Linear Fixtures: Their larger surface area naturally spreads the brightness over a wider plane, reducing "pixelation" glare. Many linear models are designed with recessed LEDs or specialized diffusers that maintain high efficacy while keeping UGR low.

Compliance, Controls, and Rebate Optimization

For B2B buyers, performance must be balanced with regulatory compliance. Modern energy codes, such as ASHRAE Standard 90.1-2022, mandate strict Lighting Power Density (LPD) limits and the use of automatic controls.

DLC Premium and Utility Rebates To maximize ROI, fixtures should be listed on the DesignLights Consortium (DLC) Qualified Products List (QPL). The DLC 5.1 Premium standard is particularly important as it requires fixtures to demonstrate not only high efficacy but also advanced dimming and control capabilities.

  • 0-10V Dimming: Standard in both UFO and linear pro-grade fixtures. This allows for multi-level lighting (e.g., 100% for games, 30% for cleaning/maintenance).
  • Occupancy Sensors: Essential for gyms that are used intermittently. Integrated sensors can reduce energy consumption by an additional 20-30% beyond the LED conversion alone.

The Title 24 Factor In jurisdictions like California, Title 24, Part 6 requires specific control strategies, including daylight harvesting if the gym has skylights or high windows. Linear fixtures are often easier to integrate into these "zoned" control strategies due to their row-based wiring.

Indoor commercial gym/training area lit by modular LED hexagon ceiling fixtures providing bright, even illumination over cardio machines, kettlebells and marked functional-training floor; useful for garage/shop lighting and hexagon lighting product pages, highlighting aesthetic DIY kits and shop lighting applications.

Implementation Checklist for Facility Managers

When evaluating a lighting bid for a large athletic space, do not rely solely on the "total lumens" figure. Use this expert checklist to ensure the layout will perform in the real world:

  1. Request the .IES File: Ensure the contractor has run a simulation in software like AGi32. A fixture's published beam angle can be misleading if the photometric distribution has sharp cut-offs.
  2. Verify the Uniformity Gradient: Ask for a point-by-point foot-candle map. Look for areas where the light level drops by more than 20% between two adjacent 10'x10' squares.
  3. Check UGR Ratings: For gyms, aim for a UGR of 22 or lower. High-output UFOs without diffusers often exceed 25, which is uncomfortable for athletes.
  4. Confirm UL/ETL Certification: Ensure the entire fixture—not just the driver—is listed under UL 1598 for safety.
  5. Evaluate Spacing vs. Mounting Height: In a UFO grid, spacing should generally equal mounting height (1:1 ratio). In a linear row, rows should be spaced 1.5 times the mounting height, with fixtures within the row spaced closer together.

Summary of Selection Logic

Choosing between a UFO grid and a linear row pattern depends on the facility's specific priorities:

  • Choose a UFO Grid if: The ceiling height is over 35 feet, the space is perfectly square, or the installation budget is strictly limited by the number of mounting points (labor costs). UFOs are the "workhorses" of industrial lighting and provide excellent wide-area coverage.
  • Choose a Linear Row if: The facility hosts competitive sports or broadcast events, the ceiling is between 15 and 30 feet, or long-term energy savings and rapid ROI are the primary drivers. The superior uniformity and lower wattage per fixture of the linear approach typically provide a better athlete experience and a faster payback.

Ultimately, the "best" layout is the one validated by photometric data. Before finalizing a purchase, always compare the ROI calculations and uniformity maps of both configurations. A small increase in initial fixture count can often pay for itself within the first year through reduced energy demand and enhanced facility utility.


Disclaimer: This article is for informational purposes only and does not constitute professional engineering or electrical advice. Always consult with a licensed electrical contractor and lighting designer to ensure compliance with local building codes and safety standards.